MG3690B Series
RF/Microwave Signal Generator
Model Number: MG3690B Series
Frequency Range: 0.1 Hz to 325 GHz

Documentation & DownloadsDocumentation & Downloads

This Product is Obsolete
Replacements:


Description

The MG3690B series of broadband signal generators covers both RF and microwave frequencies from 0.1 Hz to 70 GHz. For mmW frequencies, the MG3690B’s coverage can be extended up to 325 GHz or beyond, with external multipliers. Thus, the MG3690B series is an ideal signal source for both RF and microwave requirements, fully configurable from simple to high performance applications.

The MG3690B microwave signal generator series also offers the highest output power, best-in-class spectral purity, and fastest switching speed. For example, the MG3692B can provide guaranteed +23 dBm at 20 GHz with -94 dBc/Hz phase noise at 1 kHz offset while typically switching at 5 ms per point! This level of performance eliminates the need for external amplification, enables the verification the toughest spectral purity requirements, and greatly reduces test times. If 5 ms per point is not fast enough then switch to the optional analog ramp sweep for even faster measurements.

The MG3690B also offers a full suite of modulation capabilities for signal simulations from simple to the most complex. These modulation options include Amplitude (AM), Frequency (FM), Phase (ØM), and Pulse (PM).  The MG3690B can be configured to perform these modulations simultaneously via either internal or external waveform generators. For IQ modulation, the IF input option allows the easy up-conversion of an externally IQ-modulated RF signal.

The MG3690B replaces the original MG3690A signal generator, offering higher output power and faster frequency switching speed. Whether you have a requirement for a high power local oscillator that can deliver up to a half watt typically at 20 GHz, or you want to decrease the test time of an ATE station by greater than two folds, the MG3690B will exceed your expectations. The MG3690B preserves full backward compatibility with the MG3690A and previous 68C/69B series of RF and microwave signal generators.

The MG3690B family of microwave signal generators is not only ideal in performance for nearly every application, but it is also extremely configurable to meet your exact needs. Choose between many performance and capability options to minimize your investment level while maintaining confidence to affordably upgrade for future needs. The MG3690B is also reliable and backed with a complete 3-year warranty as a standard feature.

The MG3690B is the ideal signal generator.

RF & Microwave Applications:
Satellite R&D and manufacturing
Electronic warfare/jamming R&D and manufacturing
Military maintenance
Microwave component R&D and manufacturing
IC testing for OEMs


Features

Highly configurable to meet your exact needs
Choose from these options to configure a custom signal generator system for today's application and budget, while maintaining value for future upgrades.

Six frequency models-

    MG3691B

    2 to 10 GHz

    MG3692B

    2 to 20 GHz

    MG3693B

    2 to 30 GHz

    MG3694B

    2 to 40 GHz

    MG3695B

    2 to 50 GHz

    MG3696B

    2 to 67 GHz *

* Operational to 70 GHz

  • Frequency coverage options-

10 MHz to 2 GHz coverage, best modulation performance

opt. 5

10 MHz to 2 GHz coverage, lowest phase noise performance

opt. 4

10 MHz to 2 GHz coverage, Analog Sweep Capability

opt. 6

mmW multiplier bias, for external multipliers

opt. 18

0.1 Hz to 10 MHz, for audio frequencies

opt. 22

  • Performance enhancing options-

Mechanical and electronic step attenuators

opt. 2

Ultra-low phase noise, >2 GHz

opt. 3

High power output

opt. 15

High stability time base

opt. 16

  • Added capabilities options-

    IF Input for IQ Upconvert

    opt. 7

    Power Monitor for internal power measurement capability

    opt. 8

    User-Defined Modulation Waveform Software

    opt. 10

    FM/Phase Modulation (externally driven)

    opt. 12

    AM (externally driven)

    opt. 14

    Scan Modulation (externally driven)

    opt. 20

    Pulse Modulation (externally driven)

    opt. 26

    Internal LF and Pulse Generators (for internally driven modulation)

    opt. 27

    Analog Modulation Suite - adds Internal and External AM/FM/ØM/PM

    opt. 28

     Low Phase Noise

     opt. 30

  • Mechanical options-

Rack mount configurations

opt. 1

Rear Panel RF output configuration

opt. 9

Delete front panel

opt. 17

 Design Tools by Phase Matrix  Interactive Design Tools


 

National Instruments

 MG3690B LabVIEW Driver

 MG369xB LabWindows / CVI Driver



Related Literature / Software:

  • RF and Microwave Instruments Product Brochure
  • Brochure
  • MG3690B RF/Microwave Signal Generators Handout
  • Brochure
  • MG3690B RF/Microwave Signal Generators Brochure
  • Brochure
  • MG3690B RF/Microwave Signal Generators Technical Data Sheet
  • Data Sheet
  • Reference Charts for RF & Microwave Communications
  • Instruction Sheet
  • Electronic Measuring Instruments Catalog
  • Catalog
  • Understanding Frequency Accuracy in Crystal Controlled Instruments Application Note
  • Application Note
  • Measuring Video Feedthrough in Pulsed Signals Application Note
  • Application Note
  • MG3690C Synthesizer IVI Drivers
  • Driver/Software/Firmware
  • Complex Modulation Software
  • Driver/Software/Firmware
  • MG3690B Signal Generator Operation Manual
  • Operations Manual
  • MG369xB SCPI Programming Manual
  • Programming Manual
  • MG369xB GPIB Programming Manual
  • Programming Manual
  • RF/Microwave Signal Generator MG369xB Maintenance Manual
  • Maintenance Manual
  • Frost & Sullivan Award for Product Line Strategy Leadership
  • News
  • Anritsu Company Introduces Synthesizers with Industry-best Power and Improved Frequency Switching Speed
  • News


    FAQs:

  • Is there a GPIB command that would update the MG3690B display while running the instrument in remote?
  • FAQ
  • What are the maximum input levels for the Pulse Trigger Input on the MG3692B?
  • FAQ
  • Can the Power Monitor, Option 8, on the MG3690B be externally triggered?
  • FAQ
  • Why is option 7 or 15 not allowed with option 18 in the MG3690B Signal Generator?
  • FAQ
  • Does the MG3690B understand SCPI commands?
  • FAQ
  • What is the procedure to clear any user setups from the memory of a MG369XA or MG369XB Series Signal Generator?
  • FAQ
  • What is your confidence level of uncertainty statement?
  • FAQ
  • What are the types and sizes of the memories that MG3690A and MG3690B series Signal Generators have?
  • FAQ
  • What type of RF output connector is standard for the MG3691B?
  • FAQ
  • How do I set a MG3690B series Signal generator to factory defaults settings?
  • FAQ


    This Product is Obsolete
    Replacements:

    Home  |  Company  |  Products  |  Documents  |  ShopAnritsu  |  News  |  Events  |  Support  |  Contact  |  SiteMap  |  Contact WebMaster