Covering the 100 kHz to 3.0 GHz frequency range, the MS2711D handheld spectrum analyzer is the proven solution for installing, provisioning, maintaining and troubleshooting wireless systems and RF frequency spectrum interference issues. This portable spectrum analyzer features a built-in standard preamplifier in a compact, handheld design that can go “anywhere, anytime” with no backpack required. Ideal for field environments and applications that require mobility, such as site surveys and on-site system testing. The MS2711D can be ordered with optional built-in transmission measurement that adds scalar analysis capability from 25 MHz to 2.5 GHz.

The MS2711D spectrum analyzer also features several dedicated smart measurements that make testing cellular, DCS/PCS and WLAN systems and other wireless systems easier than ever before. Measurements include received signal strength (RSSI), channel power, adjacent channel power ratio (APCR), and occupied bandwidth measurements that can confirm the distortion level or channel power level of an AMPS, TDMA, CDMA or GSM transmitter. Additionally, the MS2711D can locate and identify out-of-band spurious signals when analyzing a wireless base station transmitter, while the field strength mode allows users to measure propagation and coverage, or to pinpoint electromagnetic (EM) leakage in broadcast systems. Measurement of carrier to interference ratio is included. This measurement is targeted for measurements of 802.11 a, b, and g access points. Other features include trace averaging for more accurate noise measurements; a multilingual user interface with on-screen menus and messaging in 6 different languages; and a 50-ohm interface that is adaptable to 75-ohms, enabling users to conduct measurements of 75-ohm systems without sacrificing measurement accuracy. The High Accuracy Power Meter (Option 19) provides true RMS measurements from 50 MHz to 6 GHz.

The MS2711D includes data analysis software, soft carrying case, rechargeable/field-replaceable battery, AC/DC power supply, and 12.5V automobile cigarette lighter adapter and users guide.

Applications

Convenient operating procedures, high sensitivity, and excellent repeatability enable the MS2711D to pinpoint the smallest system performance degradation and allow for easy verification of system compliance. This spectrum analyzer is an ideal solution for cellular providers, land mobile operators, and military spectrum analysis. Typical applications include:

  • Interference detection features include AM/FM/SSB demodulation and interfering signal type determination for cellular signals.
  • Transmitter Spectrum Analysis - occupied bandwidth, channel power, adjacent channel power ratio (ACPR), modulation and antenna gain/isolation measurements
  • Received Signal strength (RSSI) - location and identification of in-band interference and out-of-band spurious signals; modulation identification, and spectral masks,
  • Signal Strength Mapping - to determine the most suitable location for antennas, base stations and repeaters
  • Stimulus-response measurements - for component test.


  • Features
    • Handheld, battery-operated design
    • Built in pre-amplifier (standard)
    • Lightweight at only 4.9 lbs
    • Noise Level < -135 dBm typical (preamp on)
    • Quick Zoom-in, Zoom-out display in 1-2-5 sequence
    • RBWs: 100 Hz to 1 MHz in 1-3 sequence
    • VBWs: 3 Hz to 1 MHz in 1-3 sequence
    • Automatic, manual, and dynamic attenuator control
    • Amplitude Accuracy +/- 0.5 dB typical
    • Dedicated smart measurements
    • Trace Averaging
    • Reference Level Offset
    • Trace Overlay
    • Multilingual User Interface (English, Chinese, French, German, Japanese, Spanish)
    • Store up to 15 measurement test set-ups
    • Save up to 200 measurement traces
    • Alphanumeric labeling of saved measurements
    • Automatic time and date stamp of saved data
    • Rechargeable/field-replaceable battery
    • 6 Markers, limit lines and segmented limit lines
    • 50-ohm Interface standard (75-ohm interface capability - instrument internally corrects for adapter loss)
    • RS232 Interface
    • Built in AM, FM and SSB demodulation
    • Transmission Measurement, 25 MHz to 2.5 GHz (option 21)
    • Power Meter (option 29)

    Options


    Add these options to expand functionality in your spectrum analyzer:

    • Option 19 - High Accuracy Power Meter (sensor PSN50 not included)
    • Option 21 - Transmission Measurement provides tracking output from 25 MHz to 2.5 GHz
    • Option 25 - Interference Analysis provides spectrogram display, RSSI (Received Signal Strength Indication) and signal strength with audio output for radio direction finding.
    • Option 27 - Channel Scanner displays amplitude of multiple channels of supported air interface standards.
    • Option 29 - Power Meter provides channelized power measurements (no sensor or detector needed)

    Training Courses

    • Interference Analysis
      Interference Analysis Using a Handheld Spectrum Analyzer is an intense two-day instructor led training course focusing on Spectrum Analyzer operation basics and signal interference analysis.

     


    Related Literature / Software:

  • Spectrum Analysis Solutions
  • Brochure
  • Interference Analysis Solutions
  • Brochure
  • Base Station Analysis Solutions
  • Brochure
  • Introduction to RF & Microwave Spectrum Analysis Training Course
  • Brochure
  • RF and Microwave Instruments Product Brochure
  • Brochure
  • Introduction to Spectrum Analysis Training Course
  • Brochure
  • Handheld RF and Microwave Analyzers Family Brochure
  • Brochure
  • Interference Analysis Training Course
  • Brochure
  • Spectrum Master MS2711D
  • Brochure
  • UltraWide Omnidirectional Antenna 2000-1616 Technical Data Sheet
  • Data Sheet
  • Ultra Wideband Log Periodic Antenna 2000-1617 Technical Data Sheet
  • Data Sheet
  • High Accuracy Power Meter PSN50 Technical Data Sheet
  • Data Sheet
  • Directional Antennas Technical Data Sheet
  • Data Sheet
  • FCN4760 Frequency Converter
  • Data Sheet
  • Support for Microwave Bands
  • Data Sheet
  • Anritsu Handheld Analyzers Solutions Poster
  • Instruction Sheet
  • Reference Charts for RF & Microwave Communications
  • Instruction Sheet
  • Handheld Software Tools Versions Guide
  • Instruction Sheet
  • Electronic Measuring Instruments Catalog
  • Catalog
  • Practical Tips on Measuring Interference Application Note
  • Application Note
  • Fundamentals of Interference in Wireless Networks Application Note
  • Application Note
  • Direction Finding Application Note
  • Application Note
  • Advanced Spectrum Analyzer Marker Measurements Application Note
  • Application Note
  • Power Measurements Application Note
  • Application Note
  • Broadcast Measurements Application Note
  • Application Note
  • Practical Tips on Transmission Measurements Application Note
  • Application Note
  • Practical Tips on Measuring Interference - Spectrum Master MS2711B
  • Application Note
  • Must-Have Reference for Wireless Communications
  • White Paper
  • Technical Note - The Basis of Spectrum Analyzers
  • Technical Note
  • Download Handheld Software Tools
  • Driver/Software/Firmware
  • Master Software Tools v2.18
  • Driver/Software/Firmware
  • FCN4760 Frequency Converter Module User's Guide
  • User Guide
  • Spectrum Master MS2711D User Guide
  • User Guide
  • 2-Port Transmission Measurement Guide
  • Operations Manual
  • Power Meter Measurement Guide
  • Operations Manual
  • Spectrum Analyzer Measurement Guide
  • Operations Manual
  • Programming Manual for the MS2711D Spectrum Master
  • Programming Manual
  • Spectrum Master MS2711D Maintenance Manual
  • Maintenance Manual


    FAQs:

  • What methodolgy is used to derive GPS data for the Master products?
  • FAQ
  • Are Anritsu PC applications for downloading files from the Site Master supported on 64 bit Windows OS's?
  • FAQ
  • When I turn on Marker Noise, the detector changes to RMS, why is that?
  • FAQ
  • How do I calculate Noise Power density (dBm/Hz) from a measurement made with the MS2711D or MS272x spectrum analyzer?
  • FAQ
  • Why does my MS2721B give me an input saturation warning when other instruments don't?
  • FAQ
  • I'm making a field strength measurement and see an area of the display that is much higher than the rest. Why does it do that?
  • FAQ
  • On the S332D,and the MS2711D can we connect 5 dBm and 24 V DC to the SPA input? How does this affect the accuracy?
  • FAQ
  • Which software do I use to update the firmware for Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • When I'm using my MS2711D sometimes the noise floor changes value by 25 dB. Why is that?
  • FAQ
  • Can I use Master Software Tools to retrieve saved measurements from my Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • Which software do I use to update the firmware for Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • I have been using Handheld Software Tools to retrieve measurement saved in my Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products . Can I use Master Software Tools to do the same?
  • FAQ
  • Does the internal power meter (option 29) of S332D require an external detector to measure power?
  • FAQ
  • Can I enter the sweep time manually in Spectrum Analyzer mode?
  • FAQ
  • I am using the MS2711 and MS2711D Spectrum Analyzers. The MS2711 does not have an option to set manual attenuation like the MS2711D does. Is it possible to add this feature to the MS2711?
  • FAQ
  • Is it possible to set more than 5 segmented limit lines on MS2711D?
  • FAQ
  • Can the power level of the Signal Generator - MS2711D (With CW Generator Option) be changed remotely when you are programming the unit?
  • FAQ
  • How many data points are there on my MS2711D spectrum analyzer trace?
  • FAQ
  • How to calculate the proper sweep time for MS2711D?
  • FAQ
  • Can I use the InstaCal I got with my new S331C on my S331B? How about my S114C?
  • FAQ
  • What are the Universal Serial Bus(USB) to Serial Adapter data rate transmission limitations?
  • FAQ
  • How do you determine if my Site Master adapters are working properly?
  • FAQ
  • Is there a way to return the Site Master, MT8212B, S412D or MS2711x to factory defaults?
  • FAQ

    Home  |  Company  |  Products  |  Documents  |  ShopAnritsu  |  News  |  Events  |  Support  |  Contact  |  SiteMap  |  Contact WebMaster