S114C
Site Master™ Cable and Antenna Analyzer
Model Number: S114C
Frequency Range: 2 MHz to 1600 MHz

Documentation & DownloadsDocumentation & Downloads

This Product is Obsolete
Replacements:


Description

Covering the 2 MHz to 1.6 GHz frequency band, the Site Master S113C/S114C site management tools are designed to accurately locate and identify RF cable feed-line and antenna system faults. These models are ideally suited for any experience user in commissioning and maintenance of today's wireless communication system infrastructure including VHF, cellular and GPS applications.

S113C measurement capability includes return loss, VSWR, cable loss and distance-to-fault (DTF) analysis. Patented RF interference rejection enables accurate, repeatable measurements in the presence of high RF activity. Data analysis software enables assessment of system trends, problems, and performance in addition to professional report generation. An optional power meter is available to make power measurements quickly and easily.

The S114C features spectrum analysis capability in addition to return loss, VSWR, cable loss and distance-to-fault (DTF) measurements, allowing technicians and field engineers the ability to easily identify and solve RF system problems such as coverage, interference, and other path related signal problems. S114C spectrum analysis ranges from 100 kHz to 1.6 GHz.

The S113C/S114C models include data analysis software, soft carrying case, rechargeable/field-replaceable battery, AC/DC power supply, 12.5V automobile cigarette lighter adapter and users guide.


Features
  • Handheld, battery-operated design
  • Lightweight at only 4.5 lbs. (including battery)
  • Superior Immunity to RF interference
  • Long Range, High Resolution Fault Location
  • Pop-up cable menus containing over 70 cable types
  • Multilingual user interface; English, French, Chinese, Japanese, Spanish, German
  • Intuitive and easy to use with On-Screen Test Set-Ups
  • Saves 10 Measurement Test Set-Ups
  • Saves up to 200 Measurement Traces
  • Alphanumeric Labeling of Saved Measurements
  • Automatic Time and Date Stamp of Saved Data
  • Rechargeable, Field Replaceable Battery
  • Distance Measurement in Feet and Meters
  • Information Screens Provide Cable Attenuation and Velocity of Propagation values
  • 6 Markers, Limit Lines, and Segmented Limit Lines
  • RF Power Monitor Option (option 5)
  • RS232 Interface

Related Literature / Software:

  • RF and Microwave Instruments Product Brochure
  • Brochure
  • Site Master Training Course
  • Brochure
  • Handheld Software Tools Versions Guide
  • Instruction Sheet
  • Handheld Code Loader Readme file
  • Instruction Sheet
  • Electronic Measuring Instruments Catalog
  • Catalog
  • FlexCal Broadband Calibration and Measurement Application Note
  • Application Note
  • Anritsu's Site Master Handheld Cable and Antenna Analyzers
  • Application Note
  • Insertion Loss Measurement Methods Application Note
  • Application Note
  • Download Handheld Code Loader
  • Driver/Software/Firmware
  • Download Handheld Software Tools
  • Driver/Software/Firmware
  • Site Master S113C, S114C, S331C, and S332C
  • User Guide
  • Site Master S113C, S114C, S331C, S332C, S113CQ, S114CQ, and S115BQ
  • Programming Manual
  • Site Master S114C/S332C Maintenance Manual
  • Maintenance Manual


    FAQs:

  • What is the maximum input power at the load port without damage of 2000-767/2000-768 Open/Short/ Load (DIN Type)?
  • FAQ
  • My traces are saved in .MDB format on my PC. How do I convert these traces to .DAT files?
  • FAQ
  • When creating Custom Cable list using Handheld Software Tools to upload to a Site Master, what is the maximum number of cable types that can be stored in the Site Master (current platform and old platform)?
  • FAQ
  • Will a Polyphaser alter the return loss of an antenna sweep?
  • FAQ
  • What is the Return Loss specification for 2000-767/2000-768 Open/Short/Load?
  • FAQ
  • I have saved my Site Master traces to a database. How do I view the files using HHST?
  • FAQ
  • Does Handheld Software Tools work with Microsoft Vista?
  • FAQ
  • My S113C will not allow me to set the F2 (upper) frequency to 2.4GHz.
  • FAQ
  • Can I charge my Site Master battery and the spare battery at the same time?
  • FAQ
  • After saving a sweep in the Site Master, how can we change the resolution from 130 to 259 points without re-sweeping the coax hard line?
  • FAQ
  • My captured traces on Handheld Software Tools do not look same as they are saved in Site Master. Scale has changed (vertical side).
  • FAQ
  • Why does it look like a short is occurring in my Antenna when I'm doing a DTF?
  • FAQ
  • I am trying to place my marker on a specific frequency, but the marker only allows me to go to a specified frequency (ie: I want to place it on 1950.3, but the marker jumps to 1949.xx or 1950.9x). Why does it do this?
  • FAQ
  • What USB to Serial Adapters will work with my Sitemaster?
  • FAQ
  • Why doesn't my USB to Serial adapter work?
  • FAQ
  • Why doesn't my USB to Serial adapter work?
  • FAQ
  • What type of interface cable is needed for connectiing a computer to the Site Master?
  • FAQ
  • What do I need if my Laptop doesn't have a Serial interface connection?
  • FAQ
  • What is the part number for a replacement battery for the 'A' and non-lettered Site Masters?
  • FAQ
  • When installing Software Tools on a Windows 2000 operating system, the installer might find versions of DLLs on your PC that are out of date.
  • FAQ
  • Why is my Site Master display blank on power-up?
  • FAQ
  • Why is my unit giving bad readings?
  • FAQ
  • Marker and trace data values are truncated to the right of the decimal (comma) for both Frequency and Amplitude. This occurs in German and French operating system Regional Settings.
  • FAQ
  • Can I use the InstaCal I got with my new S331C on my S331B? How about my S114C?
  • FAQ
  • Is the v6.41 software backward compatible with the v6.4?
  • FAQ
  • What is the little double arrow 'C' symbol on my display mean?
  • FAQ
  • What will be the benefit for me to install the Site Master Code Loader?
  • FAQ
  • Is it possible to recall traces once they have been deleted from the Site Master 251 series?
  • FAQ
  • I left my Site Master on a bench and went to lunch. It's not sweeping anymore. What's wrong? How do I get it to sweep again?
  • FAQ
  • How to interpret traces?
  • FAQ
  • How do I get the graph from Software Tools into a Word Document? Into Excel?
  • FAQ
  • Why is my display dark when it is too hot or too cold?
  • FAQ
  • Can I use any standard extension cable with my Site Master?
  • FAQ
  • How long does it take to warm up my SiteMaster?
  • FAQ
  • Using version 6.41 software, I do not seem to be able to overlay two plots by the drop and drag method described in the help file. Can you suggest what I may be doing wrong?
  • FAQ
  • How do I know if my Site Master battery is charging?
  • FAQ
  • What are the Universal Serial Bus(USB) to Serial Adapter data rate transmission limitations?
  • FAQ
  • How do you determine if my Site Master adapters are working properly?
  • FAQ
  • How can I find out if there is a Software update available for my SiteMaster Software Tools? How do I get the update?
  • FAQ
  • Why can't I use the Power Monitor Mode?, it says "Power Monitor Not Installed", I have a connector, what else do I need?
  • FAQ
  • When I open a plot in the Site Master Software Tools I am unable to move any of the markers away from the left or right margin of the plot.
  • FAQ
  • When I select to display a plot from a database, the plot will not display and my mouse cursor remains an hour-glass.
  • FAQ
  • When testing sites on power transmission towers do I need to worry about ESD damaging the Site Master?
  • FAQ
  • What causes an Integrator Failure?
  • FAQ


    This Product is Obsolete
    Replacements:

    Home  |  Company  |  Products  |  Documents  |  ShopAnritsu  |  News  |  Events  |  Support  |  Contact  |  SiteMap  |  Contact WebMaster