S820D
Broadband Site Master™ Microwave Transmission Line and Antenna Analyzer
Model Number: S820D
Frequency Range: 2 MHz - 20 GHz

Documentation & DownloadsDocumentation & Downloads

This product is configurable
Configure Now


Description

Site Master S810D covering 2 MHz to 10.5 GHz, and S820D covering 2 MHz - 20.0 GHz, are the most accurate, reliable and convenient microwave transmission line and antenna analyzers available for installation, verification, troubleshooting, and repair of microwave communication systems.  An "anytime, anywhere" solution designed for the rugged challenges faced by field technicians working with wireless and defense communications systems.

Standard measurement capabilities includes VSWR, return loss, cable loss, and distance-to-fault (DTF) analysis, using frequency domain reflectometry (FDR) technology. Patented RF interference rejection enables accurate measurements in the presence of high RF activity. Both coaxial and waveguide connections are supported. Handheld Software Tools (HHST) is a free data analysis software utility that enables assessment of system trends, problems, and performance in addition to professional report generation.

Optional capabilities include 2 MHz frequency extension, power monitor, N(f) test port connector, 2-port cable loss, and GPS receiver. The 2 MHz frequency extension offers additional frequency coverage beyond the standard 25 MHz starting frequency. The power monitor is available to make power measurements quickly and easily. The 2-port cable loss employs an external CW source for conducting true 2-port cable loss measurements to 20 GHz. The built-in GPS receiver provides location information that is stamped on each trace and saved with archived data.

Broadband Site Master S810D and S820D utilizes 1-port vector error correction solving the most common and the most difficult accuracy problems of field test equipment operation and thus, improves system quality and reduces maintenance expenses. Difficult test specifications are easy to verify. Vector error correction and a simple, friendly user interface within the S810D and S820D further improves the quality and convenience of measurements compared to traditional scalar techniques. Vector error correction also improves the quality of Distance-To-Fault data. Not only is the reflection magnitude more accurate, the waveguide dispersion correction for fault distance (different frequencies travel at different speeds) is also more accurate and repeatable.

The S810D and S820D include PC based data analysis software, soft carrying case, rechargeable battery, AC/DC power supply, ruggedized adapter k(m) to N(f) Anritsu part number 34RKNF50, 12 V automobile cigarette lighter adapter and users guide.Visit Base Station Central!

Options:

 

  • 2 MHz Low Frequency Extension (S8X0D/2)
  • Power Monitor (S8X0D/5, Detector not included)
  • Replaces Standard K(f) Test Port Connector with N(f) (S8X0D/11NF)
  • 2-port SMA (f) Cable Loss (S8X0D/22SF)
  • 2-port N (f) Cable Loss (S8X0D/22NF)
  • GPS Receiver (S8X0D/31, includes 2000-1410GPS Antenna)

Applications:

 

Defense and Aerospace:  Installation/Maintenance and Fault Detection

  • Microwave cables in aircraft
  • Microwave cables on board ships
  • Microwave antennas

Wireless Microwave Backhaul:  Installation/Maintenance and Fault Detection

  • Point-to-point radios
  • Microwave antennas
  • Microwave cables

Other Facilities Using Microwave Links as a Communication Backbone

  • Utility companies:  gas, oil
  • Other government facilities

Features
  • Broadest frequency range available in the market: 2 MHz to 20 GHz 
  • Standard TFT daylight viewable color display
  • Real-time measurement speed
  • Real-time DTF calculations
  • Utilizes Frequency Domain Reflectometry (FDR) Technology
  • Only handheld product that supports waveguide
  • True 2-port cable loss measurements for long microwave cable applications
  • Power monitor offers power measurements in the field
  • GPS receiver provides precise location information to overlay on measurements
  • Handheld, battery-operated design
  • Lightweight at only 5 lbs. (including battery)
  • Superior Immunity to RF interference
  • Locate long range problems with 517 data points
  • Multilingual user interface; English, French, Chinese, Japanese, Spanish, German
  • Saves 21 Measurement Test Set-Ups
  • Saves up to 200 Measurement Traces
  • Clearly defined user interface for Coaxial cable and Waveguide media
  • Pop-up menus for cable list, waveguide list, and compatible flange list
  • Quickly select cable/waveguide type and test parameters without setup error
  • Alphanumeric Labeling of Saved Measurements
  • Automatic Time and Date Stamp of Saved Data
  • Rechargeable, Field Replaceable Battery
  • Distance Measurement in Feet and Meters
  • 6 Markers, Limit Lines, and Segmented Limit Lines
  • RS232 Interface
  • Handheld Software Tools (HHST) Features

  • Trace overlay for on-screen comparison of current measurements to previously saved measurements
  • Store an unlimited number of data traces for comparison to historical performance
  • HHST supports downloading traces from Site Master or uploading traces to Site Master with a single menu selection
  • Waveguide editor added to HHST to support downloading and uploading waveguide list and saving as a file
  • Cable editor added to HHST to support downloading and uploading cable list and saving as a file

    Compare the Site Master Models


  • Related Literature / Software:

  • Cable & Antenna Analysis Solutions
  • Brochure
  • RF and Microwave Instruments Product Brochure
  • Brochure
  • Broadband Site Master S810D/S820D Brochure/Datasheet
  • Brochure
  • Handheld RF and Microwave Analyzers Family Brochure
  • Brochure
  • Site Master Cable Assemblies
  • Data Sheet
  • Handheld Code Loader Readme file
  • Instruction Sheet
  • Electronic Measuring Instruments Catalog
  • Catalog
  • Power Measurements Application Note
  • Application Note
  • Distance To Fault
  • Application Note
  • Reflectometer Measurements - Revisited Application Note
  • Application Note
  • Anritsu's Site Master Handheld Cable and Antenna Analyzers
  • Application Note
  • Insertion Loss Measurement Methods Application Note
  • Application Note
  • Download Handheld Code Loader
  • Driver/Software/Firmware
  • Master Software Tools v2.18
  • Driver/Software/Firmware
  • Site Master S810D and S820D User's Guide
  • User Guide
  • S8x0D Programming Manual
  • Programming Manual
  • Broadband Site Master S8x0D Maintenance Manual
  • Maintenance Manual
  • in-site Newsletter - Master Users Group
  • News


    FAQs:

  • What is the meaning of the LED indicators on the optional battery charger?
  • FAQ
  • What happens if the battery of my site master is completely discharged?
  • FAQ
  • What methodolgy is used to derive GPS data for the Master products?
  • FAQ
  • Are Anritsu PC applications for downloading files from the Site Master supported on 64 bit Windows OS's?
  • FAQ
  • How do I reduce the side lobes in a DTF on a Site Master?
  • FAQ
  • Does Anritsu have T-shape Open/ Short / Load with K type connector for Broadband Site Masters (S810D/S820D)?
  • FAQ
  • What is a one port cable loss test?
  • FAQ
  • Can a .csv file that was converted from a .vna file of a VNA master be converted back to .vna using Master Software Tools?
  • FAQ
  • Can I sweep antennas close to another RF source?
  • FAQ
  • Can I sweep an antenna with a TMAS on the line?
  • FAQ
  • Which offset short should I use for insertion loss measurements on Waveguide cable...the 1/8 offset short or the 3/8 offset short?
  • FAQ
  • Does your Handheld Software Tools and Master Software Tools work on Macintosh computers?
  • FAQ
  • Will the InstaCal Calibration Module, ICN50, work on the S810D/S820D?
  • FAQ
  • Which software do I use to update the firmware for Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • Can you capture the power monitor (option 5) measurements by using the "Capture Current Plot to Screen F2" function of Handheld Software Tools?
  • FAQ
  • Can I use Master Software Tools to retrieve saved measurements from my Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • Which software do I use to update the firmware for Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products?
  • FAQ
  • I have been using Handheld Software Tools to retrieve measurement saved in my Site Master (S331D, S332D, S311D, S312D, S325D, S810D and S820D), Spectrum Master (MS2711D) and Cell Master (MT8212B) products . Can I use Master Software Tools to do the same?
  • FAQ
  • When using a Sitemaster, what is the maximum cable loss I should measure using the 1 port method?
  • FAQ
  • When I sweep a cable using my S820D can I use the the 1/8 short or my 3/8 short as my actual short at the end of my cable?
  • FAQ
  • My traces are saved in .MDB format on my PC. How do I convert these traces to .DAT files?
  • FAQ
  • What are the specifications for the SC5237 (6 dB offset termination) and SC5270 (20 dB offset termination)?
  • FAQ
  • The measurement range of the Power Monitor Option (5) for Site Masters is -50 to +20 dBm. Can we measure power greater than +20dBm?
  • FAQ
  • I am trying to download 12 traces from my S331D to a database using HHST I consistently get an error on 3 traces although not the same 3 when I try to do this. I also tried to capture the plots to screen but the same thing happens. I am using the latest firmware on the handheld and have the current version of HHST.
  • FAQ
  • When creating Custom Cable list using Handheld Software Tools to upload to a Site Master, what is the maximum number of cable types that can be stored in the Site Master (current platform and old platform)?
  • FAQ
  • Will a Polyphaser alter the return loss of an antenna sweep?
  • FAQ
  • What is the Return Loss specification for 2000-767/2000-768 Open/Short/Load?
  • FAQ
  • I have saved my Site Master traces to a database. How do I view the files using HHST?
  • FAQ
  • Does Handheld Software Tools work with Microsoft Vista?
  • FAQ
  • We are testing Andrews EW64 Waveguide with 164DET (CPR137G) type flange with Site Master 820C. We need to know the corresponding part numbers for the 1/8 short, 3/8 short, precision load, and waveguide to coax N(m) adapter that we need for calibration.
  • FAQ
  • Can I charge my Site Master battery and the spare battery at the same time?
  • FAQ
  • Does Anritsu have T-shape Calibration Components (Open, Short and Load) for Broadband Site Masters (S810D/S820D)?
  • FAQ
  • After saving a sweep in the Site Master, how can we change the resolution from 130 to 259 points without re-sweeping the coax hard line?
  • FAQ
  • My captured traces on Handheld Software Tools do not look same as they are saved in Site Master. Scale has changed (vertical side).
  • FAQ
  • Why does it look like a short is occurring in my Antenna when I'm doing a DTF?
  • FAQ
  • I am trying to place my marker on a specific frequency, but the marker only allows me to go to a specified frequency (ie: I want to place it on 1950.3, but the marker jumps to 1949.xx or 1950.9x). Why does it do this?
  • FAQ
  • What USB to Serial Adapters will work with my Sitemaster?
  • FAQ
  • Why doesn't my USB to Serial adapter work?
  • FAQ
  • Why doesn't my USB to Serial adapter work?
  • FAQ
  • Why don't I use an Open/Short/Load procedure for waveguide calibrations?
  • FAQ
  • What type of interface cable is needed for connectiing a computer to the Site Master?
  • FAQ
  • What do I need if my Laptop doesn't have a Serial interface connection?
  • FAQ
  • What is the part number for a replacement battery for the 'A' and non-lettered Site Masters?
  • FAQ
  • When installing Software Tools on a Windows 2000 operating system, the installer might find versions of DLLs on your PC that are out of date.
  • FAQ
  • Why is my Site Master display blank on power-up?
  • FAQ
  • Why is my unit giving bad readings?
  • FAQ
  • Marker and trace data values are truncated to the right of the decimal (comma) for both Frequency and Amplitude. This occurs in German and French operating system Regional Settings.
  • FAQ
  • Can I use the InstaCal I got with my new S331C on my S331B? How about my S114C?
  • FAQ
  • Is the v6.41 software backward compatible with the v6.4?
  • FAQ
  • What is the little double arrow 'C' symbol on my display mean?
  • FAQ
  • What will be the benefit for me to install the Site Master Code Loader?
  • FAQ
  • Can you use a one load if you calibrate with a different load?
  • FAQ
  • Is it possible to recall traces once they have been deleted from the Site Master 251 series?
  • FAQ
  • I left my Site Master on a bench and went to lunch. It's not sweeping anymore. What's wrong? How do I get it to sweep again?
  • FAQ
  • When performing a line sweep the unit blinks "DX" where the "Hold" is displayed.
  • FAQ
  • In DTF mode, I chose a cable from the cable list, but the cable loss that is given does not match the cable loss that is in my catalog. What is wrong?
  • FAQ
  • How to interpret traces?
  • FAQ
  • How do I get the graph from Software Tools into a Word Document? Into Excel?
  • FAQ
  • Why does my DTF Trace "creep up" on long cables?
  • FAQ
  • Why is my display dark when it is too hot or too cold?
  • FAQ
  • Can I use any standard extension cable with my Site Master?
  • FAQ
  • How long does it take to warm up my SiteMaster?
  • FAQ
  • How accurate (in feet) is the DTF measurement?
  • FAQ
  • Using version 6.41 software, I do not seem to be able to overlay two plots by the drop and drag method described in the help file. Can you suggest what I may be doing wrong?
  • FAQ
  • How to interpret the presence of Connector, Jumper or Antenna using the DTF graph?
  • FAQ
  • Why is propagation velocity important for DTF, but not for Return Loss or SWR?
  • FAQ
  • There is a lot of concern about loss and reflections in the cable run to the antenna. Why don't the radio MFGs just make transmitters with more power?
  • FAQ
  • How do I know if my Site Master battery is charging?
  • FAQ
  • What are the Universal Serial Bus(USB) to Serial Adapter data rate transmission limitations?
  • FAQ
  • How do you determine if my Site Master adapters are working properly?
  • FAQ
  • How can I find out if there is a Software update available for my SiteMaster Software Tools? How do I get the update?
  • FAQ
  • How important is the calibration? I have made a Calibration for 900 band and saved the setup. Two days later I recall setup and (without Calibrating) used to measure feeder. Do you recommend this procedure?
  • FAQ
  • I just calibrated my SiteMaster but after about 20 min it says "Calibration OFF", Just how big is the valid calibration temperature window. How can I see this information?
  • FAQ
  • Why does my SiteMaster say "Calibration OFF", wasn't it calibrated at the factory?
  • FAQ
  • What is the most common cause of antenna/cable failure?
  • FAQ
  • Why can't I use the Power Monitor Mode?, it says "Power Monitor Not Installed", I have a connector, what else do I need?
  • FAQ
  • How can I check the accuracy of the InstaCal calibration?
  • FAQ
  • When I open a plot in the Site Master Software Tools I am unable to move any of the markers away from the left or right margin of the plot.
  • FAQ
  • Why can't I go more then 86 ft on a DTF measurement.
  • FAQ
  • When I select to display a plot from a database, the plot will not display and my mouse cursor remains an hour-glass.
  • FAQ
  • When testing sites on power transmission towers do I need to worry about ESD damaging the Site Master?
  • FAQ
  • What causes an Integrator Failure?
  • FAQ

    Home  |  Company  |  Products  |  Documents  |  ShopAnritsu  |  News  |  Events  |  Support  |  Contact  |  SiteMap  |  Contact WebMaster