Search Results: Anritsu
  Results 1 - 20 of about 1150 for Anritsu.

Most Popular Frequently Asked Questions
Are Anritsu PC applications for downloading files from the Site ...
Currently Anritsu does not but is working diligently to provide a solution. ..
Faqs
Are CDMA measurements supported in the Anritsu BTS Master?
Yes, CDMA measurements are supported in the BTS Master MT8222A as well as the Cell Master MT8212B.  Additionally both platforms also support EVDO measurements...
Faqs [ More results >> ]
Can Anritsu provide accredited calibration for the 3652 cal kit?
Anritsu is not currently accredited to provide service for this particular product. For available services, please visit the quality site at www.us.anritsu.com or contact our service centers...
Faqs
What are the different types of verification kits you offer for ...
Anritsu offers a complete line of coaxial verification kits to confirm your systems performance. Here are the three different types of verification kits we offer for the Scorpion series VNA: 3663R, Type N verification Kit 3666R, SMA/3.5 mm Verification Kit 3667R, GPC-7 Verification Kit ..
Faqs [ More results >> ]
Does Anritsu have a sensor for the ML24xxx line of power meters ...
At this time Anritsu does not have a power sensor for the ML24xxx line of power meters that will measure up to 65GHz. 50GHz is the upper limit for sensors that Anritsu offers...
Faqs
I recently erased stored traces on my MT8212B Cell Master. Is ...
Once a trace has been erased the file cannot be recovered...
Faqs
Does the MT8212B Cell Master require GPS when building CDMA PN ...
Yes, the Cell Master MT8212B does require GPS to do in building CDMA PN searches.  This requirement is not due to limitations in the test equipment but is driven by the CDMA technology which requires a sync source...
Faqs [ More results >> ]
I want to purchase a spectrum analyzer that supports quasi-peak ...
Yes, the MS272XB family of Spectrum Analyzers supports quasi-peak detection...
Faqs
What is necessary to add the W-CDMA Measurement Hardware after the ...
Option21 W-CDMA Measurement Hardware retrofit of MT8820A is required. The installation is carried out at Anritsu service site...
Faqs [ More results >> ]
I would like a hybrid Single Mode/Multi Mode OTDR, but can I get ...
This is possible on the CMA5000 by installing two OTDR modules. One module would support 1310nm, 1490nm, and 1550nm Singlemode, while the other would support 850nm and 1300nm Multimode. Customer support can assist you in selecting the right models and configurations to meet your specific requirements pleas..
Faqs
What is the description of the MU967701A? What is its ...
The MU967701A must be used with the MP9677B. Because it is the clock recovery circuit which has 80MHz bandwidth for jitter measurement of 10GHz. Please refer to the data sheet for more detail...
Faqs [ More results >> ]
I am trying to download around 70 plots from an S331D to my laptop ...
On the S331D delete the displays that are showing the weird characters with lines missing. Delete all that are not normal looking and try the download after the corrupt displays are deleted...
Faqs
Can the MP1026 unit be used to test DCD (Duty Cycle Distortion) ...
Yes. The MP1026A can perform Duty Cycle Distortion (DCD) measurements. DCD is a component of the Data Dependent Jitter. Duty Cycle Distortion is a measure of the time separation between the rising edge and falling edge at the 50% level of the eye diagram. To measure the DCD, the 50% level of the edges is cal..
Faqs [ More results >> ]
I cannot seem to open my traces on the CMA 5000/4500. The trace ...
The .OSDS extension is used to indicate an OTDR Setup Configuration File. This type of file is used to save all of the OTDR set-up parameters (such as range, resolution, average times, pulswidth, wavelength, etc) but not the actual OTDR trace data. This type of file is used to save and recall the way your O..
Faqs
How can I update the firmware of an MT8820A?
The software for updating is provided on a CD-ROM.Copy the contents of the CD-ROM to a PCMCIA memory card (supplied with the MT8820A) on your PC. Then follow the directions to install the software into the MT8820A via the memory card. Please refer to the instruction manual which is supplied together with the..
Faqs [ More results >> ]
Can the MP1763B / MP1764A Sync on Burst data?
Burst measurement capability is a standard feature in the MP1763B/MP1764A. Our 12.5 Gb/s BERT, is excellent for Burst measurements, because it has very fast Sync time. The MP1764A syncs quickly on both standard PRBS and User Defined patterns. This ability to Sync quickly on bursted data is one of our key ..
Faqs
Does 25G Mux card have an Emphasis Control option?
Yes, two channel (25G Mux) card has Emphasis Control option MU182021A-040.  One channel (25G Mux) card has no Emphasis Control option...
Faqs [ More results >> ]
Can these GPIB command remote control options be added after ...
Yes, all of these remote control options can be added after purchase. But they must be added by an Anritsu service engineer...
Faqs
For the MD1230A, how does software upgrade take place?
Software for the MD1230A is normally upgraded at an Anritsu Customer Service Center...
Faqs [ More results >> ]